Program Version,EnergyPlus 3.1.0.027, 01/04/2010 4:00 PM,IDD_Version 3.1.0.027 ** Warning ** Timestep: Requested number (2) is less than the suggested minimum of 4. ** ~~~ ** Please see entry for Timestep in Input/Output Reference for discussion of considerations. ************* Beginning Zone Sizing Calculations ** Warning ** Site:GroundTemperature:BuildingSurface: Some values fall outside the range of 15-25C. ** ~~~ ** These values may be inappropriate. Please consult the Input Output Reference for more details. ** Warning ** Weather file location will be used rather than entered Location object. ** ~~~ ** ..Location object=35 BAYLAWN DRIVE ** ~~~ ** ..Weather File Location=TORONTO BUTTONVILLE - - IWEC Data WMO#=- ** Warning ** Standard Time Meridian and Time Zone differ by more than 1, Difference="2.0" ** ~~~ ** Solar Positions may be incorrect ** Warning ** CAUTION -- Interzone surfaces are occuring in the same zone(s). ** ~~~ ** ...use Output:Diagnostics,DisplayExtraWarnings; to show more details on individual occurrences. ************* Note that the following warning(s) may/will occur if you have not enclosed your zone completely. ** Warning ** Entered Zone Volumes differ from calculated zone volume(s). ** ~~~ ** ...use Output:Diagnostics,DisplayExtraWarnings; to show more details on individual zones. ** Warning ** DeterminePolygonOverlap: Too many vertices [>23] detected in an overlap calculation. Use Output:Diagnostics,DisplayExtraWarnings; for more details. ** Warning ** GetDetailedDaylighting: Reference point Y Value outside Zone Min/Max Y, Zone=MASTERWASHROOM ** ~~~ ** ...Y Reference Point= 8.16, Zone Minimum Y= 8.34, Zone Maximum Y= 13.12 ** ~~~ ** ...Y Reference Distance Outside MinimumY= 0.1863 m. ** Warning ** Detailed daylighting will not be done for zone=FIRSTLAUNDRY ** ~~~ ** because it has no associated exterior windows. ** Warning ** Detailed daylighting will not be done for zone=MASTERWASHROOM ** ~~~ ** because it has no associated exterior windows. ** Warning ** Detailed daylighting will not be done for zone=CLOSET ** ~~~ ** because it has no associated exterior windows. ** Warning ** Calculated design cooling load for zone=BASEMENTCIRCULATION is zero. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs. ** Warning ** Calculated design cooling load for zone=BASEMENTBEDROOM is zero. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs. ** Warning ** Calculated design cooling load for zone=BASEMENTWASHROOM is zero. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs. ************* Beginning System Sizing Calculations ** Warning ** DXFOut: Could not triangulate surface="Mir-BUILDING 1 - COMPONENT BLOCK 2 - SURFACE 2 (28)", type="Detached Shading:Building", check surface vertex order(entry) ** ~~~ ** ...use Output:Diagnostics,DisplayExtraWarnings; to show more details on individual surfaces. ** Warning ** DXFOut: Could not triangulate surface="S_FIRSTKITCHEN_0_4_0", type="Floor", check surface vertex order(entry) ** Warning ** DXFOut: Could not triangulate surface="E_12411_19_8_0", type="Floor", check surface vertex order(entry) ************* Testing Individual Branch Integrity ************* All Branches passed integrity testing ************* Testing Individual Supply Air Path Integrity ************* All Supply Air Paths passed integrity testing ************* Testing Individual Return Air Path Integrity ************* All Return Air Paths passed integrity testing ************* No node connection errors were found. ** Warning ** Processing Monthly Tabular Reports: OccupantComfortDataSummaryMonthly ** ~~~ ** ..Variable name=FANGERPMV not valid for this simulation. ** ~~~ ** ..i.e., Variable name=FIRSTLAUNDRY:FANGERPMV not valid for this simulation. ** ~~~ ** ..Variables not valid for this simulation will have "[Invalid/Undefined]" in the Units Column of the Table Report. ** Warning ** UtilityCost:Tariff: The meter chosen COOLING:ELECTRICITY is not typically used with the buyFromUtility option. Usually ** ~~~ ** the Electricity:Facility meter or the ElectricityPurchased:Facility is selected when the sellToUtility option is used. ** ~~~ ** In UtilityCost:Tariff named HVAC_ELEC_CON ** Warning ** UtilityCost:Tariff: The meter chosen COOLING:ELECTRICITY is not typically used with the buyFromUtility option. Usually ** ~~~ ** the Electricity:Facility meter or the ElectricityPurchased:Facility is selected when the sellToUtility option is used. ** ~~~ ** In UtilityCost:Tariff named HVAC_ELEC_DEM ** Warning ** UtilityCost:Tariff: Meter referenced is not present due to a lack of equipment that uses that energy source:WATER HEATER:WATERSYSTEMS:GAS ** ~~~ ** In UtilityCost:Tariff named DHW_GAS_CON ** Warning ** UtilityCost:Tariff: Meter referenced is not present due to a lack of equipment that uses that energy source:PUMPS:ELECTRICITY ** ~~~ ** In UtilityCost:Tariff named PUMPS_CON ** Warning ** UtilityCost:Tariff: The meter chosen PUMPS:ELECTRICITY is not typically used with the buyFromUtility option. Usually ** ~~~ ** the Electricity:Facility meter or the ElectricityPurchased:Facility is selected when the sellToUtility option is used. ** ~~~ ** In UtilityCost:Tariff named PUMPS_CON ** Warning ** UtilityCost:Tariff: Meter referenced is not present due to a lack of equipment that uses that energy source:PUMPS:ELECTRICITY ** ~~~ ** In UtilityCost:Tariff named PUMPS_DEM ** Warning ** UtilityCost:Tariff: The meter chosen PUMPS:ELECTRICITY is not typically used with the buyFromUtility option. Usually ** ~~~ ** the Electricity:Facility meter or the ElectricityPurchased:Facility is selected when the sellToUtility option is used. ** ~~~ ** In UtilityCost:Tariff named PUMPS_DEM ** Warning ** UtilityCost:Tariff: The meter chosen FANS:ELECTRICITY is not typically used with the buyFromUtility option. Usually ** ~~~ ** the Electricity:Facility meter or the ElectricityPurchased:Facility is selected when the sellToUtility option is used. ** ~~~ ** In UtilityCost:Tariff named FANS_CON ** Warning ** UtilityCost:Tariff: The meter chosen FANS:ELECTRICITY is not typically used with the buyFromUtility option. Usually ** ~~~ ** the Electricity:Facility meter or the ElectricityPurchased:Facility is selected when the sellToUtility option is used. ** ~~~ ** In UtilityCost:Tariff named FANS_DEM ** Warning ** UtilityCost:Tariff: Meter referenced is not present due to a lack of equipment that uses that energy source:INTERIOREQUIPMENT:ELECTRICITY ** ~~~ ** In UtilityCost:Tariff named APPLIANCES_CON ** Warning ** UtilityCost:Tariff: The meter chosen INTERIOREQUIPMENT:ELECTRICITY is not typically used with the buyFromUtility option. Usually ** ~~~ ** the Electricity:Facility meter or the ElectricityPurchased:Facility is selected when the sellToUtility option is used. ** ~~~ ** In UtilityCost:Tariff named APPLIANCES_CON ** Warning ** UtilityCost:Tariff: Meter referenced is not present due to a lack of equipment that uses that energy source:INTERIOREQUIPMENT:ELECTRICITY ** ~~~ ** In UtilityCost:Tariff named APPLIANCES_DEM ** Warning ** UtilityCost:Tariff: The meter chosen INTERIOREQUIPMENT:ELECTRICITY is not typically used with the buyFromUtility option. Usually ** ~~~ ** the Electricity:Facility meter or the ElectricityPurchased:Facility is selected when the sellToUtility option is used. ** ~~~ ** In UtilityCost:Tariff named APPLIANCES_DEM ** Warning ** UtilityCost:Tariff: The meter chosen INTERIORLIGHTS:ELECTRICITY is not typically used with the buyFromUtility option. Usually ** ~~~ ** the Electricity:Facility meter or the ElectricityPurchased:Facility is selected when the sellToUtility option is used. ** ~~~ ** In UtilityCost:Tariff named LIGHTING_CON ** Warning ** UtilityCost:Tariff: The meter chosen INTERIORLIGHTS:ELECTRICITY is not typically used with the buyFromUtility option. Usually ** ~~~ ** the Electricity:Facility meter or the ElectricityPurchased:Facility is selected when the sellToUtility option is used. ** ~~~ ** In UtilityCost:Tariff named LIGHTING_DEM ** Warning ** More than 4% of time (86.4 hours) uncomfortable in one or more zones ** ~~~ ** Based on ASHRAE 55-2004 graph (Section 5.2.1.1) ** ~~~ ** During Environment [01/01 - 03/31]: TORONTO BUTTONVILLE - - IWEC Data WMO#=- ** ~~~ ** 838.0 hours were uncomfortable in zone: FIRSTLAUNDRY ** ~~~ ** 1132.0 hours were uncomfortable in zone: FIRSTWASHROOM ** ~~~ ** 412.0 hours were uncomfortable in zone: DINING ** ~~~ ** 412.0 hours were uncomfortable in zone: FIRSTKITCHEN ** ~~~ ** 684.0 hours were uncomfortable in zone: FIRSTLIVING ** ~~~ ** 684.0 hours were uncomfortable in zone: FIRSTFAMILY ** ~~~ ** 1132.0 hours were uncomfortable in zone: MASTERBEDROOM ** ~~~ ** 1132.0 hours were uncomfortable in zone: BEDROOM B ** ~~~ ** 128.0 hours were uncomfortable in zone: STUDYROOM ** ~~~ ** 656.0 hours were uncomfortable in zone: MASTERWASHROOM ** ~~~ ** 656.0 hours were uncomfortable in zone: SECONDWASHROOM ** ~~~ ** 1132.0 hours were uncomfortable in zone: BEDROOM A ************* ************* ===== Final Error Summary ===== ************* The following error categories occurred. Consider correcting or noting. ************* Interzone surfaces - different zones ************* ************* EnergyPlus Completed Successfully-- 34 Warning; 0 Severe Errors; Elapsed Time=00hr 02min 35.50sec