Abstract

Despite the proliferation of the usage of simulation programs in the conventional building design process, the use of thermal simulation programs in assessing energy and thermal performances of building designs are very limited. This thesis aims to investigate the role of thermal simulation programs in various phases of building projects‟ life cycles, and evaluate potential benefits these programs can bring. To illustrate the potential of these simulation programs, two case studies, one from the schematic design phase and the other from the post-occupancy phase, are presented. The thesis shows that, at each of these phases, thermal simulations can act as a feedback tool where performances of different strategies can be evaluated, which in turn allows energy conserving strategies to be recognized. The thesis also shows that, at the post-occupancy phase, conducting thermal simulation studies with existing buildings can also help highlight poor performances.

Blinds45Degrees_manual.idf (2447 kB)
Blinds60Degrees_automatic.idf (2446 kB)
Blinds60Degrees_manual.idf (2447 kB)
Chapter3Apartment.dsb (2756 kB)
EPS25.idf (2442 kB)
EPS50.idf (2442 kB)
EPS75.idf (2442 kB)
EPS100.idf (2442 kB)
EPS125.idf (2442 kB)
EPS150.idf (2442 kB)
ICF 50-200-50.idf (2441 kB)
ICF 62.5-200-62.5.idf (2441 kB)
ICF 75-200-25.idf (2442 kB)
InteriorInsulation25.idf (2442 kB)
InteriorInsulation75.idf (2442 kB)
InteriorInsulation125.idf (2442 kB)
InteriorInsulation175.idf (2442 kB)
InteriorInsulation225.idf (2442 kB)
Isokorb.idf (2443 kB)
Overhang0.5.idf (2565 kB)
Overhang0.idf (2327 kB)
Overhang1.5.idf (2566 kB)
Overhang1.idf (2566 kB)
Overhang2.idf (2566 kB)
SolarAbs0.25.idf (2442 kB)
SolarAbs0.45.idf (2442 kB)
SolarAbs0.75.idf (2442 kB)
SolarAbs0.875.idf (2442 kB)
WindowConfig1.idf (2471 kB)
WindowConfig2.idf (2471 kB)
WindowConfig3.idf (2474 kB)
WindowConfig4.idf (2445 kB)
WindowConfig5.idf (2445 kB)
WindowConfig6.idf (2446 kB)
AT 0.1.idf (2444 kB)
AT 0.2.idf (2443 kB)
AT 0.3.idf (2443 kB)
AT 0.4.idf (2443 kB)
Basecase.idf (2442 kB)
Blinds0Degrees_automatic.idf (2446 kB)
Blinds0Degrees_manual.idf (2447 kB)
Blinds30Degrees_automatic.idf (2446 kB)
Blinds30Degrees_manual.idf (2447 kB)
Blinds45Degrees_automatic.idf (2446 kB)
EPS175.idf (2442 kB)
EPS200.idf (2442 kB)
EPS225.idf (2442 kB)
EPS250.idf (2442 kB)
ExteriorInsulation25.idf (2442 kB)
ExteriorInsulation75.idf (2442 kB)
ExteriorInsulation125.idf (2442 kB)
ExteriorInsulation175.idf (2442 kB)
ExteriorInsulation225.idf (2442 kB)
ICF 25-200-75.idf (2442 kB)
Basecase_19SP.audit (814 kB)
Basecase_19SP.bnd (39 kB)
Basecase_19SP.csv (756 kB)
Basecase_19SP.dxf (229 kB)
Basecase_19SP.eio (161 kB)
Basecase_19SP.err (9 kB)
Basecase_19SP.eso (1125 kB)
Basecase_19SP.idf (694 kB)
Basecase_19SP.mdd (10 kB)
Basecase_19SP.mtd (83 kB)
Basecase_19SP.mtr (20 kB)
Basecase_19SP.rdd (19 kB)
Basecase_19SP.rvaudit (1 kB)
Basecase_19SP.shd (207 kB)
Basecase_19SP.svg (7 kB)
Basecase_19SPMeter.csv (4 kB)
Basecase_19SPSsz.csv (3 kB)
Basecase_19SPTable.csv (189 kB)
Basecase_19SPZsz.csv (39 kB)
Chapter4House.dsb (1124 kB)
Multizone.idf (734 kB)
Singlezone.audit (815 kB)
Singlezone.bnd (39 kB)
Singlezone.csv (3126 kB)
Singlezone.dxf (229 kB)
Singlezone.eio (161 kB)
Singlezone.err (8 kB)
Singlezone.eso (4816 kB)
Singlezone.idf (695 kB)
Singlezone.mdd (10 kB)
Singlezone.mtd (83 kB)
Singlezone.mtr (604 kB)
Singlezone.rdd (19 kB)
Singlezone.rvaudit (1 kB)
Singlezone.shd (207 kB)
Singlezone.svg (7 kB)
SinglezoneMeter.csv (155 kB)
SinglezoneSsz.csv (3 kB)
SinglezoneTable.csv (189 kB)
SinglezoneZsz.csv (39 kB)


Share

COinS